TEKNECMIX · PNEUMATIC & ELECTRIC INDUSTRIAL MIXERS
TEKNECMIXINDUSTRIAL MIXINGRequest a quote ↗

How to Mix a Closed-Head 55-Gallon (200 L Class) Drum Through a Bung Opening

By TEKNECMIX

Use the clear bore of the bung and the complete folded impeller envelope to assess fit before buying. A nominal 2-inch bung does not establish that model 03 can pass through it. The 03 bridge-mount mixer is a candidate when the opening, bridge seating, shaft reach and running clearance all check out.

Engineering selection table

How to Mix a Closed-Head 55-Gallon (200 L Class) Drum Through a Bung Opening
Measure or confirm What to record Model 03 reference
Bung and adapter Narrowest clear bore and depth through the entire path Get the exact folded assembly dimensions before choosing a bung
Bridge support Clear span and stable mounting surfaces 600 mm bridge plate
Shaft reach Mounting height, internal depth and fill range 880 mm shaft
Operating clearance Wall, bottom and obstructions at the intended position 250 mm expanded impeller diameter
Compressed air Available pressure and flow under load 3/4 HP air drive; 0.6 MPa working pressure; confirm airflow

Fit-review checklist

  1. Send a top photo of the drum and a close-up of the narrowest opening with a ruler.
  2. Confirm folded insertion dimensions and expanded clearance with the supplier for the exact assembly.
  3. Confirm support, working depth and starting liquid condition before following the supplied installation instructions.

View the 03 pneumatic closed-head drum mixer · Compare bridge and clamp mounts.

Frequently asked questions

Will model 03 fit a 2-inch bung?

Fit requires the actual clear bore and the confirmed folded envelope of the complete assembly. Treat 2 inches as the nominal fitting size and check adapters and recesses.

Is a 200 L drum exactly 55 US gallons?

200 L is approximately 52.8 US gallons. Verify the actual drum and working fill independently of its commercial label.

Request a TEKNECMIX application review